Voltage interface module, TeSys island, 690VAC 47-63 Hz, Isolated switching input for safe stop | TPRVM001
- TeSys island voltage interface module, 100-690V / 47-63Hz. Connected to a TPRBC bus coupler it measures the mains voltages powering the loads. It provides the voltage values for power and energy calculation, calculates the RMS values and phase sequence.
TPRVM001
Voltage Interface Module TeSys Island, 100-690V / 47-63Hz. The module measures the voltage in the load supply network. One module is required for each island, regardless of the number of configured avatars. It provides voltage measurements for power and energy calculations, including active and reactive power, RMS values, and phase sequence. Voltage measurement range: 100-690 V +/- 5%, frequency measurement range: 47-63 Hz +/- 1 Hz in single-phase or three-phase systems. Installation is performed on a DIN rail along with other modules in the TeSys Island configuration. It has certifications of compliance with multiple standards (IEC, UL, CSA, CCC, EAC) and Green Premium (RoHS/REACh). It holds a level 2 Achilles cybersecurity certification.
Basic Parameters: |
Product range: |
|
Product name: |
|
Short product name: |
|
Product or component type: |
|
Module function: |
Monitoring of the mains voltage powering the island |
Reporting of the voltage to the bus coupler to enable power & energy monitoring |
Calculation of RMS phase voltages, voltage phase sequence, fundamental frequency |
Identification of dip and swell events level and duration |
|
Rated operational voltage [Ue]: |
|
Rated insulation voltage [Ui]: |
690 V in accordance with IEC 61010-1 |
|
Rated impulse withstand voltage [Uimp]: |
6 kV in accordance with IEC 61010-1 |
|
Monitoring type: |
Phase voltage 100...690 V |
Phase frequency 47...63 Hz |
Phase sequence |
|
Voltage: |
|
Frequency: |
|
Additional Parameters: |
Rated supply voltage [Us]: |
24 V DC supplied by the bus coupler |
|
Current consumption: |
|
Power loss in watts (W): |
|
Dimensions |
Width: |
|
Height: |
|
Depth: |
|
Mounting method: |
Horizontal and vertical (35 mm symmetrical rail) |
|
Environmental Conditions |
Degree of protection: |
|
Ambient temperature (operation): |
|
Ambient temperature (storage): |
|
Benefits
- Precise voltage monitoring in single-phase and three-phase systems.
- Detection of network events such as voltage fluctuations.
- Integration with the TeSys island system for real-time energy monitoring.
- Compact and durable design, easy to install, and resistant to harsh conditions.
- Compliance with international standards, ensuring safety and versatility.
Wszystkie parametry znajdują się poniżej w karcie produktu
Do you need help? Do you have any questions?Ask a question and we'll respond promptly, publishing the most interesting questions and answers for others.