  • MCR current measuring transducer, programmable and configurable, for measuring direct, alternating and distorted currents, with relay and transistor output, input current 0...0.2 A to 0...11 A, unconfigured
1 550,35 zł
net / szt.
Lowest price in 30 days before discount: / szt.
Regular price: / szt.
14 days for easy returns
This product is not available in a stationary store
Safe shopping
Deferred Payments. Buy now, pay later, if you don't return it
Buy now, pay later - 4 steps
When choosing a payment method, select PayPo.PayPo - buy now, pay later
PayPo will pay your bill in the store.
On the PayPo website, verify your information and enter your social security number.
After receiving your purchase, you decide what suits you and what doesn't. You can return part or all of your order - then the amount payable to PayPo will also be reduced.
Within 30 days of purchase, you pay PayPo for your purchases at no additional cost. If you wish, you spread your payment over installments.

AC current measuring transducers and AC/DC current measuring transducers

Here you will find the appropriate measuring transducer for measuring direct, alternating, and distorted currents. The offer includes various options for a wide measurement range: from very low currents, starting from 0 mA to 100 mA, up to higher currents up to 600 A. To quickly add additional measuring points in existing installations, it is worth using versions with a removable Rogowski sensor.
AC and AC/DC current measuring transducers

Product features:

Product type:

Current measuring transducer

Electrical parameters

Supply voltage range:

from 20 V DC to 30 V DC

Maximum current consumption:

< 50 mA

Total error:

≤1.5% (temperature range)

Maximum power loss under rated conditions:

2.2 W

Test voltage output/power supply:

500 V AC (50 Hz, 60 s)

Test voltage input/output:

4 kV AC (50 Hz, 60 s)

Test voltage input/power supply:

4 kV AC (50 Hz, 60 s)

Response to step input (10-90%):

300 ms
40 ms (DC)

Typical temperature coefficient:

<0.025 %/K

Maximum transmission error:

≤ 0.5 % (of rated range under normal conditions)

Rated insulation voltage:

300 V AC (to ground)

Input data

Input current range:

from 0 A AC/DC to 11 A AC/DC (Permissible continuous overload: 120%)

Measuring range:

from 0 A AC/DC to 1 A AC/DC
from 0 A AC/DC to 5 A AC/DC
from 0 A AC/DC to 10 A AC/DC

Adjustment range, min. input current:

from 0 mA AC/DC to 200 mA AC/DC

Adjustment range, max. input current:

from 0 A AC/DC to 11 A AC/DC

LSB: Current

1 µA (1 A)
2 µA (2 A)
5 µA (5 A)
10 µA (10 A)
50 µA (50 A)
100 µA (100 A)

Current overload capacity:

2 x IN (continuous)

Current carrying capacity:

20 x IN (1 s)

Measured frequency range:

from 15 Hz to 400 Hz

Trigger threshold:

2% (of the rated value of the measuring range 1/5/10 A)

Output data: Relay

Contact type:

1 changeover contact

Contact material:

AgSnO, hard gold plating

Maximum switching voltage:

30 V AC
36 V DC
250 V AC

Continuous current carrying capacity of the contact:

50 mA (with gold layer, 30 V AC / 36 V DC)
2 A (with damaged gold layer, 250 V AC)

Output data: Transistor

Continuous load current:

80 mA (not short-circuit proof)

Output voltage range:

from 19 V to 29 V (Supply voltage - 1 V)

Threshold setting range:

from 1% to 110%

Response delay setting range:

from 0.1 s to 20 s

Output data: Voltage/Current

Configurable/Programmable:

yes, not configured

Output signal voltage:

from 0 V to 5 V
from 1 V to 5 V
from 0 V to 10 V
from 2 V to 10 V
from -5 V to 5 V
from -10 V to 10 V
from 10 V to 0 V
from 10 V to 2 V
from 10 V to -10 V
from 5 V to 0 V
from 5 V to 1 V
from 5 V to -5 V

Output signal current:

from 0 mA to 20 mA
from 4 mA to 20 mA
from 20 mA to 0 mA
from 20 mA to 4 mA

Voltage output load/power:

> 10 kΩ

Current output load/power:

< 500 Ω (20 mA)

Dimensions

Width:

22.5 mm

Height:

99 mm

Depth:

114.5 mm

Mounting method:

DIN rail mounting

Ambient conditions

Protection rating:

IP20

Ambient temperature:

from -20 °C to 60 °C

Benefits

  • Device configuration via DIP switch or using MCR/PI-CONF-WIN software
  • Three-way isolation
  • True RMS measurement
pixel
Wszystkie parametry znajdują się poniżej w karcie produktu
Do you need help? Do you have any questions?Ask a question and we'll respond promptly, publishing the most interesting questions and answers for others.
Ask a question
If this description is not sufficient, please send us a question to this product. We will reply as soon as possible. Data is processed in accordance with the privacy policy. By submitting data, you accept privacy policy provisions.
This page uses cookie files to provide its services in accordance to Cookies Usage Policy. You can determine conditions of storing or access to cookie files in your web browser.
Close