MCR-S-1-5-UI-SW-DCI-NC - Current measuring transducer | 2814731
- MCR current measuring transducer, programmable and configurable, for measuring direct, alternating and distorted currents, with relay and transistor output, input current 0...0.2 A to 0...11 A, unconfigured
AC current measuring transducers and AC/DC current measuring transducers
Here you will find the appropriate measuring transducer for measuring direct, alternating, and distorted currents. The offer includes various options for a wide measurement range: from very low currents, starting from 0 mA to 100 mA, up to higher currents up to 600 A. To quickly add additional measuring points in existing installations, it is worth using versions with a removable Rogowski sensor.
Product features: |
Product type: |
Current measuring transducer |
|
Electrical parameters |
Supply voltage range: |
|
Maximum current consumption: |
|
Total error: |
≤1.5% (temperature range) |
|
Maximum power loss under rated conditions: |
|
Test voltage output/power supply: |
|
Test voltage input/output: |
|
Test voltage input/power supply: |
|
Response to step input (10-90%): |
|
Typical temperature coefficient: |
|
Maximum transmission error: |
≤ 0.5 % (of rated range under normal conditions) |
|
Rated insulation voltage: |
|
Input data |
Input current range: |
from 0 A AC/DC to 11 A AC/DC (Permissible continuous overload: 120%) |
|
Measuring range: |
from 0 A AC/DC to 1 A AC/DC |
from 0 A AC/DC to 5 A AC/DC |
from 0 A AC/DC to 10 A AC/DC |
|
Adjustment range, min. input current: |
from 0 mA AC/DC to 200 mA AC/DC |
|
Adjustment range, max. input current: |
from 0 A AC/DC to 11 A AC/DC |
|
LSB: Current |
1 µA (1 A) |
2 µA (2 A) |
5 µA (5 A) |
10 µA (10 A) |
50 µA (50 A) |
100 µA (100 A) |
|
Current overload capacity: |
|
Current carrying capacity: |
|
Measured frequency range: |
|
Trigger threshold: |
2% (of the rated value of the measuring range 1/5/10 A) |
|
Output data: Relay |
Contact type: |
|
Contact material: |
|
Maximum switching voltage: |
|
Continuous current carrying capacity of the contact: |
50 mA (with gold layer, 30 V AC / 36 V DC) |
2 A (with damaged gold layer, 250 V AC) |
|
Output data: Transistor |
Continuous load current: |
80 mA (not short-circuit proof) |
|
Output voltage range: |
from 19 V to 29 V (Supply voltage - 1 V) |
|
Threshold setting range: |
|
Response delay setting range: |
|
Output data: Voltage/Current |
Configurable/Programmable: |
|
Output signal voltage: |
from 0 V to 5 V |
from 1 V to 5 V |
from 0 V to 10 V |
from 2 V to 10 V |
from -5 V to 5 V |
from -10 V to 10 V |
from 10 V to 0 V |
from 10 V to 2 V |
from 10 V to -10 V |
from 5 V to 0 V |
from 5 V to 1 V |
from 5 V to -5 V |
|
Output signal current: |
from 0 mA to 20 mA |
from 4 mA to 20 mA |
from 20 mA to 0 mA |
from 20 mA to 4 mA |
|
Voltage output load/power: |
|
Current output load/power: |
|
Dimensions |
Width: |
|
Height: |
|
Depth: |
|
Mounting method: |
|
Ambient conditions |
Protection rating: |
|
Ambient temperature: |
|
Benefits
- Device configuration via DIP switch or using MCR/PI-CONF-WIN software
- Three-way isolation
- True RMS measurement

Wszystkie parametry znajdują się poniżej w karcie produktu
Do you need help? Do you have any questions?Ask a question and we'll respond promptly, publishing the most interesting questions and answers for others.