QUINT4-PS/3AC/48DC/20 - Power supply | 2904627
- QUINT POWER power supply with primary circuit keying, selectable output characteristics, SFB (Selective Fuse Breaking) technology and NFC interface, input: 3-phase, output: 48 V DC / 20 A
Power supplies
Power supplies
Our power supplies are reliable and ideally suited for any application. In our diverse product portfolio, you will find DIN-rail power supplies that vary in design, power and features. This makes them an excellent choice for a wide range of industries, such as automotive, mechanical engineering, process industries, and for the shipbuilding industry.
Product |
Product type: |
|
Product family: |
|
AC mode |
Input voltage range: |
The range is from 3X 400 V AC to 500 V AC |
The range is from 2X 400 V AC to 500 V AC |
|
Frequency range : |
50 Hz to 60 Hz |
Tolerance ±10 Hz |
|
Power backup time: |
type. 26 ms (3x 400 V AC) |
type. 26 ms (3x 480 V AC) |
|
Current consumption: |
type. 3x 1.8 A (400 V AC) |
type. 3x 1.5 A (480 V AC) |
type. 2x 3 A (400 V AC) |
type. 2x 2.5 A (480 V AC) |
type. 3x 1.5 A (500 V AC) |
type. 2x 2.4 A (500 V AC) |
|
Rated power consumption : |
|
Protection system : |
Protection against transient currents; Varistor, spark gap gassed |
|
DC mode |
Input voltage range: |
The range is from ± 260 V DC to 300 V DC |
Tolerance -13% ... +30 |
|
Current consumption: |
type. 2.2 A (±260 V DC) |
type. 1.9 A (±300 V DC) |
|
Rated power consumption : |
|
Output data |
Efficiency: |
type. 95.9 % (400 V AC) |
type. 96.2 % (480 V AC) |
|
Short circuit resistance and idle test: |
|
Output power: |
|
Start-up time: |
< 1 s (UOut (10 % ... 90 %)) |
|
High reliability: MTBF |
> 851,000 hours at 25 °C |
> 519,000 hours at 40 °C |
> 237,000 hours at 60 °C |
|
Parallel connectivity: |
Yes, for redundancy and increased power |
|
Serial connectivity: |
|
Assembly |
Mounting method |
Mounting on a mounting rail |
|
Mounting position |
DIN rail horizontal NS 35, EN 60715 |
|
Dimensions |
Width: 120 mm |
Height: 130 mm |
Depth: 125 mm |
|
Ambient conditions |
Degree of protection |
|
Ambient temperature |
from -25 °C to 70 °C (> 60 °C derating: 2.5 % for each K) |
|
Standard designation: Standards/Regulations |
Railroad applications |
EN 50121-3-2 |
EN 50121-5 |
IEC 62236-3-2 |
IEC 62236-5 |
|
Normative limitation of higher harmonics of the network current |
|
Normative electrical safety |
|
Normative low protection voltage |
IEC 61010-1 (SELV) |
IEC 61010-2-201 (PELV) |
|
Normative certain separation |
IEC 61558-2-16 |
IEC 61010-2-201 |
|
Standard - Safety requirements for equipment measuring, control, regulation and laboratory equipment |
|
Normative safety of transformers |
|
Charging the battery |
|
Approval - semiconductor industry requirements for with respect to supply voltage drops. |
SEMI F47-0706, EN 61000-4-11 |
|
Benefits
- Efficiency of 95.6% at 400 V AC, reducing energy losses and operating costs.
- Overvoltage, overload, short-circuit and output overvoltage protection.
- Possibility of short-term increase of output current and parallel connection for higher power or redundancy.
- Supports a wide range of voltage (3x 400-500 V AC, 260-300 V DC) and frequency (50-60 Hz).
- DIN rail mounting and status indication with LEDs and signal outputs.
Wszystkie parametry znajdują się poniżej w karcie produktu
Do you need help? Do you have any questions?Ask a question and we'll respond promptly, publishing the most interesting questions and answers for others.