QUINT4-PS/3AC/48DC/20 - Power supply | 2904627
- QUINT POWER power supply with primary circuit keying, selectable output characteristics, SFB (Selective Fuse Breaking) technology and NFC interface, input: 3-phase, output: 48 V DC / 20 A
Power supplies
Our power supplies are reliable and ideally suited for any application. In our diverse product portfolio, you will find DIN-rail power supplies that vary in design, power and features. This makes them an excellent choice for a wide range of industries, such as automotive, mechanical engineering, process industries, and for the shipbuilding industry. Product |
---|
Product type: | |
Product family: | |
AC mode |
---|
Input voltage range: | The range is from 3X 400 V AC to 500 V AC | The range is from 2X 400 V AC to 500 V AC | |
Frequency range : | 50 Hz to 60 Hz | Tolerance ±10 Hz | |
Power backup time: | type. 26 ms (3x 400 V AC) | type. 26 ms (3x 480 V AC) | |
Current consumption: | type. 3x 1.8 A (400 V AC) | type. 3x 1.5 A (480 V AC) | type. 2x 3 A (400 V AC) | type. 2x 2.5 A (480 V AC) | type. 3x 1.5 A (500 V AC) | type. 2x 2.4 A (500 V AC) | |
Rated power consumption : | |
Protection system : | Protection against transient currents; Varistor, spark gap
gassed | |
DC mode |
---|
Input voltage range: | The range is from ± 260 V DC to 300 V DC | Tolerance -13% ... +30 | |
Current consumption: | type. 2.2 A (±260 V DC) | type. 1.9 A (±300 V DC) | |
Rated power consumption : | |
Output data | Efficiency: | type. 95.9 % (400 V AC) | type. 96.2 % (480 V AC) | |
Short circuit resistance and idle test:: | |
output power: | |
Start-up time: | < 1 s (UOut (10 % ... 90 %)) | |
High reliability: MTBF | > 851,000 hours at 25 °C | > 519,000 hours at 40 °C | > 237,000 hours at 60 °C | |
Parallel connectivity: | Yes, for redundancy and increased power | |
Serial connectivity: | |
Assembly | Mounting method | Mounting on a mounting rail | |
Mounting position | DIN rail horizontal NS 35, EN 60715 | |
Dimensions | Width: 120 mm | Height: 130 mm | Depth: 125 mm | |
Ambient conditions | Degree of protection | |
Ambient temperature | from -25 °C to 70 °C (> 60 °C derating: 2.5 % for each K) | |
Standard designation: Standards/Regulations | Railroad applications | EN 50121-3-2 | EN 50121-5 | IEC 62236-3-2 | IEC 62236-5 | |
Normative limitation of higher harmonics of the network current | |
Normative electrical safety | |
Normative low protection voltage | IEC 61010-1 (SELV) | IEC 61010-2-201 (PELV) | |
Normative certain separation | IEC 61558-2-16 | IEC 61010-2-201 | |
Standard - Safety requirements for equipment
measuring, control, regulation and laboratory equipment | |
Normative safety of transformers | |
Charging the battery | |
Approval - semiconductor industry requirements for
with respect to supply voltage drops. | SEMI F47-0706, EN 61000-4-11 | |
Benefits
- Efficiency of 95.6% at 400 V AC, reducing energy losses and operating costs.
- Overvoltage, overload, short-circuit and output overvoltage protection.
- Possibility of short-term increase of output current and parallel connection for higher power or redundancy.
- Supports a wide range of voltage (3x 400-500 V AC, 260-300 V DC) and frequency (50-60 Hz).
- DIN rail mounting and status indication with LEDs and signal outputs.
Wszystkie parametry znajdują się poniżej w karcie produktu
Do you need help? Do you have any questions?Ask a question and we'll respond promptly, publishing the most interesting questions and answers for others.