QUINT4-PS/1AC/24DC/3.8/SC - Power supply | 2904599
- QUINT POWER primary circuit clocked power supplies, Screw connection, Mounting on mounting rail, Input: 1-phase, Output: 24 V DC / 3.8 A
Power supplies
Our power supplies are reliable and ideally suited for any application. In our diverse product portfolio, you will find DIN-rail power supplies that vary in design, power and features. This makes them an excellent choice for a wide range of industries, such as automotive, mechanical engineering, process industries, and for the shipbuilding industry. Product |
---|
Product type: | |
Product family: | |
AC mode |
---|
Input voltage range: | The range is from 100 V AC to 240 V AC | Tolerance -15% ... +10 % | |
Frequency range fN: | 50 Hz to 60 Hz | Tolerance ±10 Hz | |
Power backup time: | type. 35 ms (120 V AC) | type. 35 ms (230 V AC) | |
Current consumption: | type. 1 A (100 V AC) | type. 0.83 A (120 V AC) | type. 0.46 A (230 V AC) | type. 0.44 A (240 V AC) | |
Rated power consumption : | |
Protection system : | Protection against transient currents; Varistor | |
DC mode |
---|
Input voltage range: | The range is from 110 V DC to 250 V DC | Tolerance -20 % ... +40 % | |
Current consumption : | 0.91 A (110 V DC) | 0.4 A (250 V DC) | |
Output data | Efficiency: | type. 92.8 % (120 V AC) | type. 93.7 % (230 V AC) | |
Short circuit resistance and idle test: | |
output power: | |
Start-up time: | < 50 ms (UOut (10 % ... 90 %)) | |
High reliability: MTBF | > 1,272,000 hours at 25 °C | > 690,000 hours at 40 °C | > 271,000 hours at 60 °C | |
Parallel connectivity: | Yes, for redundancy and increased power | |
Serial connectivity: | |
Assembly | Mounting method | Mounting on a mounting rail | |
Mounting position | DIN rail horizontal NS 35, EN 60715 | |
Dimensions | | Width: 45 mm | Height: 99 mm | Depth: 90 mm | |
Ambient conditions | Degree of protection | |
Ambient temperature | from -25 °C to 70 °C (> 60 °C derating: 2.5 % for each K) | |
Standard designation: Standards/Regulations | Normative limitation of higher harmonics of the network current | |
Normative electrical safety | |
normative low protection voltage | IEC 61010-1 (SELV) | IEC 61010-2-201 (PELV) | |
Normative certain separation | IEC 61558-2-16 | IEC 61010-2-201 | |
Standard - Safety requirements for equipment
measuring, control, regulation and laboratory equipment | |
Normative safety of transformers | |
Standardized power devices for low voltage and
dC outputs | |
Benefits
- Devices with high power consumption can be put into operation thanks to dynamic power reserve.
- Preventive monitoring of functions informs of critical operating conditions before failure occurs.
- High efficiency and long service life are achieved with minimal power loss and low heat build-up.
- Compact and low-profile design saves space in the control cabinet.
- Tool-free push-in connection technology for quick and easy commissioning.
Wszystkie parametry znajdują się poniżej w karcie produktu
Do you need help? Do you have any questions?Ask a question and we'll respond promptly, publishing the most interesting questions and answers for others.