TRIO-PS-2G/1AC/12DC/5/C2LPS - Power supply | 2903157
- TRIO POWER power supply clocked in primary circuit with push-in connections for mounting on support rail, input: 1-phase, output: 12 V DC / 5 A C2LPS
Power supplies
Our power supplies are reliable and ideally suited for any application. In our diverse product portfolio, you will find DIN-rail power supplies that vary in design, power and features. This makes them an excellent choice for a wide range of industries, such as automotive, mechanical engineering, process industries, and for the shipbuilding industry. Product |
---|
Product type: | |
Product family: | |
AC mode |
---|
Input voltage range: | The range is from 100 V AC to 240 V AC | Tolerance -15% ... +10 % | |
Frequency range (fN): | 50 Hz to 60 Hz | Tolerance ±10 Hz | |
Power backup time: | > 20 ms (120 V AC) | > 110 ms (230 V AC) | |
Current consumption: | type. 1.1 A (100 V AC) | type. 1 A (120 V AC) | type. 0.6 A (230 V AC) | type. 0.6 A (240 V AC) | |
Rated power consumption: | |
Protection system: | Protection against transient currents; Varistor | |
DC mode |
---|
Input voltage range: | The range is from 99 V DC to 275 V DC | |
Current consumption: | type. 0.7 A (110 V DC) | type. 0.3 A (250 V DC) | |
Output data | Efficiency: | type. > 86 % (at 230 V AC and ratings) | |
Reducing the rating parameters: | 60 °C to 70 °C (2.5% for each K) | |
output power: | |
Start-up time: | ≤ 10 s (UOUT (10 % ... 90 %)) | |
High reliability: MTBF | > 2,900,000 hours at 40 °C | |
Parallel connectivity: | Yes, to increase power and redundancy | |
Serial connectivity: | |
Assembly | Mounting method | Mounting on a mounting rail | |
Mounting position | DIN rail horizontal NS 35, EN 60715 | |
Dimensions | Width: 30 mm | Height: 130 mm | Depth: 115 mm | |
Ambient conditions | Degree of protection | |
Ambient temperature | from -25 °C to 70 °C (> 60 °C derating: 2.5 % for each K) | |
Standard designation: Standards/Regulations | EN 60950-1 | |
Normative equipment of electronic devices
with electronic technical means | |
Normative limitation of higher harmonics of the network current | |
Normative electrical safety | |
Normative low protection voltage | IEC 62368-1 (SELV) und EN 60204-1 (PELV) | |
Normative certain separation | |
Normative safety of transformers | EN 61558-2-16 (surface and air insulation clearances only
air) | |
Benefits
- Save time and money with push-in clamps and slim design.
- Greater system availability thanks to a dynamic power reserve that is 150% of rated current for five seconds.
- Maximum flexibility thanks to a wide temperature range from -25°C to +70°C and the ability to start the device at -40°C.
- High electrical durability.
- Exceptional mechanical strength, resistant to vibration and impact.
Wszystkie parametry znajdują się poniżej w karcie produktu
Do you need help? Do you have any questions?Ask a question and we'll respond promptly, publishing the most interesting questions and answers for others.