Product
|
Product type:
|
|
Product family:
|
|
AC mode
|
Input voltage range:
|
| The range is from 3x 400 V AC to 500 V AC |
| Tolerance -20 % ... +10 % |
| The range is from 2x 400 V AC to 500 V AC |
| Tolerance -10% ... +10 % |
|
Frequency range:
|
| 50 Hz to 60 Hz |
| Tolerance ±10 Hz |
|
Power backup time:
|
| type. 29 ms (3x 400 V AC) |
| type. 26 ms (3x 480 V AC) |
|
Current consumption:
|
| type. 3x 0.5 A (400 V AC) |
| type. 3x 0.41 A (480 V AC) |
| type. 2x 1.1 A (400 V AC) |
| type. 2x 0.91 A (480 V AC) |
| type. 3x 0.4 A (500 V AC) |
| type. 2x 1.1 A (500 V AC) |
|
Rated power consumption :
|
|
Protection system :
|
| Protection against transient currents; Varistor, spark gap
gassed |
|
DC mode
|
Input voltage range:
|
| The range is from ± 260 V DC to 300 V DC |
| Tolerance -13% ... +30 % |
|
Current consumption :
|
| 0.7 A (±260 V DC) |
| 0.6 A (±300 V DC) |
|
Output data
|
Efficiency:
|
| type. 93 % (400 V AC) |
| type. 92.6 % (480 V AC) |
|
Short circuit resistance and idle test:
|
|
output power:
|
|
Start-up time:
|
| < 1 s (UOut (10 % ... 90 %)) |
|
High reliability: MTBF
|
| > 1,034,000 hours at 25 °C |
| > 654,000 hours at 40 °C |
| > 320,000 hours at 60 °C |
|
Parallel connectivity:
|
| Yes, for redundancy and increased power |
|
Serial connectivity:
|
|
Assembly
|
Mounting method
|
| Mounting on a mounting rail |
|
Mounting position
|
| DIN rail horizontal NS 35, EN 60715 |
|
Dimensions
|
|
| Width: 50 mm |
| Height: 130 mm |
| Depth: 125 mm |
|
Ambient conditions
|
Degree of protection
|
|
Ambient temperature
|
| from -25 °C to 70 °C (> 60 °C derating: 2.5 % for each K) |
|
Standard designation: Standards/Regulations
|
Railroad applications
|
| EN 50121-3-2 |
| EN 50121-4 |
| EN 50121-5 |
| IEC 62236-3-2 |
| IEC 62236-4 |
| IEC 62236-5 |
|
Normative limitation of higher harmonics of the network current
|
|
Normative electrical safety
|
|
Normative low protection voltage
|
| IEC 61010-1 (SELV) |
| IEC 61010-2-201 (PELV) |
|
Normative certain separation
|
| IEC 61558-2-16 |
| IEC 61010-2-201 |
|
Standard - Safety requirements for equipment
measuring, control, regulation and laboratory equipment
|
|
Normative safety of transformers
|
|
Charging the battery
|
|
Approval - semiconductor industry requirements for
with respect to supply voltage drops
|
| SEMI F47-0706, EN 61000-4-11 |
|