Product |
Product type: |
|
Product family: |
|
AC mode |
Input voltage range: |
| The range is from 100 V AC to 240 V AC |
| Tolerance -15% ... +10 % |
|
Frequency range fN: |
| 50 Hz to 60 Hz |
| Tolerance ±10 Hz |
|
Power backup time: |
| type. 52 ms (120 V AC) |
| type. 52 ms (230 V AC) |
|
Current consumption: |
| type. 0.37 A (100 V AC) |
| type. 0.3 A (120 V AC) |
| type. 0.17 A (230 V AC) |
| type. 0.16 A (240 V AC) |
|
Rated power consumption : |
|
Protection system : |
| Protection against transient currents; Varistor |
|
DC mode |
Input voltage range: |
| The range is from 110 V DC to 250 V DC |
| Tolerance -20 % ... +40 % |
|
Current consumption : |
| 0.32 A (110 V DC) |
| 0.14 A (250 V DC) |
|
Output data |
Efficiency: |
| type. 87.4 % (120 V AC) |
| type. 88.4 % (230 V AC) |
|
Short circuit resistance and idle test: |
|
output power: |
|
Start-up time: |
| < 50 ms (UOut (10 % ... 90 %)) |
|
High reliability: MTBF |
| > 1,890,000 hours at 25 °C |
| > 1,080,700 hours at 40 °C |
| > 473,300 hours at 40 °C |
|
Parallel connectivity: |
| Yes, for redundancy and increased power |
|
Serial connectivity: |
|
Assembly |
Mounting method |
| Mounting on a mounting rail |
|
Mounting position |
| DIN rail horizontal NS 35, EN 60715 |
|
Dimensions |
| Width: 22.5 mm |
| Height: 106 mm |
| Depth: 90 mm |
|
Ambient conditions |
Degree of protection |
|
Ambient temperature |
| from -25 °C to 70 °C (> 60 °C derating: 2.5 % for each K) |
|
Standard designation: Standards/Regulations |
Railroad applications |
| EN 50121-3-2 |
| EN 50121-5 |
| IEC 62236-3-2 |
| IEC 62236-5 |
|
Normative limitation of higher harmonics of the network current |
|
Normative electrical safety |
|
Normative low protection voltage |
| IEC 61010-1 (SELV) |
| IEC 61010-2-201 (PELV) |
|
Normative certain separation |
|
Standard - Safety requirements for equipment
measuring, control, regulation and laboratory equipment |
|
Normative safety of transformers |
|