  • For Modbus/RTU communication, with 16 inputs/outputs, pluggable to 8 PLC-INTERFACE terminal blocks, expandable to 48 inputs/outputs, real-time clock, Micro USB socket, slot for memory module and BT adapter, push-in connection
819,14 zł
net / szt.
Lowest price in 30 days before discount: / szt.
Regular price: / szt.
14 days for easy returns
This product is not available in a stationary store
Safe shopping

AC and AC/DC Current Measuring Transducers

Here you will find the right measuring transducer for measuring direct, alternating, and distorted currents. The offer includes various options for a wide measurement range: from very small currents starting at 0 mA to 100 mA, up to larger currents up to 600 A. To quickly add additional measuring points in existing installations, it is worth using variants with a removable Rogowski sensor.
AC and AC/DC Current Measuring Transducers

Product Features

Product Type:

Base unit

Product Family:

PLC logic

Electrical Parameters

Rated Insulation Voltage:

50 V

Rated Impulse Voltage:

0.8 kV

Real-time Clock:

yes

Hold Time:

96 h (capacitor)

Real-time Clock Accuracy:

±2 s/day

Rated Supply Voltage US:

24 V DC

Supply Voltage Range:

from 19.2 V DC to 26.4 V DC

Typical Input Current at UN:

40 mA

Max. Input Current at UN:

160 mA

Digital Input Data

Number of Inputs:

≤ 8 (2 configurable as analog)

Input Description:

EN 61131-2 Type 3

Input Voltage:

24 V DC

Signal Level "0":

< 5 V

Signal Level "1":

> 11 V

Input Current Signal "0":

< 1 mA

Input Current Signal "1":

2.5 mA

Analog Input Data

Number of Inputs:

≤ 2 (IN6 and IN7 configurable as analog)

Input Voltage Range:

from 0 V to 10 V

Input Resistance:

> 3.5 kΩ

PLC-INTERFACE Terminal Inputs

Number of Inputs:

≤ 8

Input Description:

technical details depend on the used PLC-INTERFACE terminal

Input Voltage:

19 V DC

Typical Current Consumption:

4 mA

Input Resistance:

< 100 mΩ

Output Data

Number of Outputs:

≤ 8

Nominal Output Voltage:

24 V DC

Nominal Current:

9 mA

Dimensions

Drawing:

Controller 1452919

Width:

50 mm

Height:

48.5 mm
111 mm (with relay)

Depth:

82.5 mm
87 mm (with relay)

Mounting Method:

Plug-in mounting

Ambient Conditions

Degree of Protection:

IP20

Ambient Temperature (operation):

from -20 °C to 50 °C

Ambient Temperature (storage/transport):

from -20 °C to 70 °C

Benefits

  • Support for 8 I/Os, including analog inputs.
  • RTC with 96-hour hold time.
  • Compact size and easy plug-in mounting.
  • Protection against overvoltage and errors.
  • Push-in terminals, LED, and USB port.
pixel
Wszystkie parametry znajdują się poniżej w karcie produktu
Do you need help? Do you have any questions?Ask a question and we'll respond promptly, publishing the most interesting questions and answers for others.
Ask a question
If this description is not sufficient, please send us a question to this product. We will reply as soon as possible. Data is processed in accordance with the privacy policy. By submitting data, you accept privacy policy provisions.