  • Current measuring transducer for sinusoidal and non-sinusoidal alternating currents, input current 0...100 A, output 4...20 mA (Loop-powered)
1 082,27 zł
net / szt.
Lowest price in 30 days before discount: / szt.
Regular price: / szt.
14 days for easy returns
This product is not available in a stationary store
Safe shopping

AC and AC/DC Current Measuring Transducers

Here you will find the right measuring transducer for measuring direct, alternating, and distorted currents. The product range includes various options for a wide measurement range: from very small currents, starting from 0 mA to 100 mA, up to larger currents up to 600 A. To quickly add additional measuring points in existing installations, it is worth using variants with a removable Rogowski sensor.
AC and AC/DC Current Measuring Transducers

Product Features:

Product Type:

Current Measuring Transducer

Electrical Parameters

Supply Voltage Range:

from 20 V DC to 30 V DC

Maximum Current Consumption:

30 mA

Maximum Power Loss Under Rated Conditions:

1 W

Test Voltage (input/output):

4.13 kV AC (50 Hz, 60 s)

Step Response (10-90%):

< 340 ms

Max. Temperature Coefficient:

< 0.025 %/K

Maximum Transfer Error:

< 1% (limit value)

Rated Insulation Voltage:

300 V AC (to ground)

Input Data

Input Current Range:

from 0 A AC ... 50 A AC
from 0 A AC ... 75 A AC
from 0 A AC ... 100 A AC

Setting Range, Min Input Current:

from 0 A AC to 50 A AC

Setting Range, Max Input Current:

from 0 A AC ... 100 A AC

Current Overload Capacity:

depending on the passed-through conductor

Current Load Capacity:

depending on the passed-through conductor

Measured Frequency Range:

from 30 Hz to 6000 Hz

Trigger Threshold:

1% (limit value)

Output Data

Output Signal (Current):

from 4 mA to 20 mA

Maximum Output Signal Current:

< 25 mA

Voltage Output Load/Power:

(UB - 12 V) x 350 / 12 A

Dimensions

Width:

55 mm

Height:

85 mm

Depth:

70.5 mm

Mounting Method:

DIN rail mounting

Environmental Conditions

Protection Rating:

IP20

Ambient Temperature:

from -20 °C to 60 °C

Benefits

  • Option to equip with flexible Rogowski coils.
  • True RMS measurement in the range from 30 to 6000 Hz.
  • Measurement range adjustment using slide switches.
pixel
Wszystkie parametry znajdują się poniżej w karcie produktu
Do you need help? Do you have any questions?Ask a question and we'll respond promptly, publishing the most interesting questions and answers for others.
Ask a question
If this description is not sufficient, please send us a question to this product. We will reply as soon as possible. Data is processed in accordance with the privacy policy. By submitting data, you accept privacy policy provisions.