- UNO POWER power supply with primary circuit keying for DIN rail mounting, IEC 60335-1, input: 1-phase, output: 12 V DC / 55 W
Power supplies
Our power supplies are reliable and ideally suited for any application. In our diverse product portfolio, you will find DIN-rail power supplies that vary in design, power and features. This makes them an excellent choice for a wide range of industries, such as automotive, mechanical engineering, process industries, and for the shipbuilding industry. Product |
---|
Product type: | |
Product family: | |
AC mode |
---|
Input voltage range: | The range is from 85 V AC to 264 V AC | |
Frequency range fN: | 50 Hz to 60 Hz | Tolerance ±10 Hz | |
Power backup time: | type. 20 ms (120 V AC) | type. 90 ms (230 V AC) | |
Current consumption: | type. 1.3 A (100 V AC) | type. 0.6 A (240 V AC) | |
Rated power consumption : | |
Protection system : | Protection against transient currents; Varistor | |
Output data | Efficiency: | type. 87 % (120 V AC) | type. 88 % (230 V AC) | |
Short circuit resistance | |
Output power: | |
Start-up time: | < 0.5 s (UOut (10 % ... 90 %)) | |
High reliability: MTBF | |
Parallel connectivity: | Yes, for redundancy and increased power | |
Serial connectivity: | |
Assembly | Mounting method | Mounting on a mounting rail | |
Mounting position | DIN rail horizontal NS 35, EN 60715 | |
Dimensions | Width: 35 mm | Height: 90 mm | Depth: 84 mm | |
Ambient conditions | Degree of protection | |
Ambient temperature | from -25 °C to 70 °C (> 60 °C derating: 2.5 % for each K) | |
Standard designation: Standards/Regulations | Standard for electrical equipment for household use | |
Normative equipment of electronic devices
with electronic technical means | |
Normative limitation of higher harmonics of the network current | |
Normative electrical safety | |
Normative low protection voltage | IEC 62368-1 (SELV) und EN 60204-1 (PELV) | |
Normative certain separation | |
Normative safety of transformers | |
Approval - semiconductor industry requirements for
with respect to supply voltage drops. | |
Benefits
- Can be quickly snapped onto a support rail.
- Increased power density, providing up to 20% more cabinet space.
- Efficiency above 90% and very low idle losses, less than 0.3 watts.
- Wide operating temperature range from -25°C to 70°C, allowing outdoor installation.