TRIO3-PS/1AC/24DC/10/4C/IOL - Power supply | 1252696
- Primary circuit clocked power supplies, TRIO POWER, Push-in terminals, 4-channel electronic switch, IO-Link, Mounting on mounting rail, Input: 1-phase, Output: 24 V DC / 10 A, 24 V DC adjustable ... 28 V DC
Power supplies
Our power supplies are reliable and ideally suited for any application. In our diverse product portfolio, you will find DIN-rail power supplies that vary in design, power and features. This makes them an excellent choice for a wide range of industries, such as automotive, mechanical engineering, process industries, and for the shipbuilding industry. Product |
---|
Product type: | |
Product family: | |
AC mode |
---|
Input voltage range: | The range is from 100 V AC to 240 V AC | Tolerance -15% ... +10 % | The range is from 115 V AC to 240 V AC | Tolerance ±10 % (UL) | |
Frequency range (fN): | 50 Hz to 60 Hz | Tolerance ±10 Hz | |
Power backup time: | type. 27 ms (120 V AC) | type. 28 ms (230 V AC) | |
Current consumption: | type. 2.6 A (100 V AC) | type. 2.2 A (120 V AC) | type. 1.2 A (230 V AC) | type. 1.1 A (240 V AC) | |
Protection system : | Protection against transient currents; Varistor | |
DC mode |
---|
Input voltage range: | The range is from 100 V DC to 240 V DC | Tolerance ±10 Hz | The range is from 160 V DC to 240 V DC | Tolerance ±10 % (UL) | |
Current consumption: | type. 2.7 A (100 V DC) | type. 1.1 A (240 V DC) | |
Output data | Efficiency: | type. 94.5 % (at 120 V AC) | type. 95.5 % (at 230 V AC) | |
Reducing the rating parameters: | < 100 V AC (1 % for each V) | > 60°C (2.5% for each K) | |
output power: | |
Start-up time: | ≤ 1 s (UOUT (10 % ... 90 %)) | |
High reliability: MTBF | > 1,300,000 hours at 25 °C | > 860,000 hours at 40 °C | > 400,000 hours at 60 °C | |
Parallel connectivity: | |
Serial connectivity: | |
Syngalization | Signaling methods | LED DC OK - signal status operation | |
Function | Visual indication of working condition. | |
Assembly | Mounting method | Mounting on a mounting rail | |
Mounting position | DIN rail horizontal NS 35, EN 60715 | |
Dimensions | Width: 68 mm | Height: 135 mm | Depth: 132 mm, 125 mm (Depth of device (DIN rail mounting)) | |
Ambient conditions | Degree of protection | |
Ambient temperature | from -25 °C to 70 °C (> 60 °C derating: 2.5 % for each K) | |
Standard designation: Standards/Regulations | EN 61010-1 | III (≤ 2000 m) | II (≤ 5000 m) | |
EN 61010-2-201 | III (≤ 2000 m) | II (≤ 5000 m) | |
Safety in the use of power supplies up to 1100 V (clearances
insulation) | |
Electrical safety | |
Equipping electrical power equipment with auxiliary electronic devices | |
Safety requirements for measuring devices,
control, regulation and laboratory | |
Very low voltage PELV | IEC 61010-1 (SELV) | IEC 61010-2-201 (PELV) | |
Safe insulation | IEC 61558-2-16 | IEC 61010-2-201 | |
Permissible levels of harmonic current emissions | |
Network fluctuation / undervoltage condition | |
Benefits
- Power supply and contactors in one device thanks to built-in multi-channel protection - provides comprehensive protection for the device.
- Reduce installation costs by as much as 70% due to reduced wiring and installation requirements.
- Improved reliability with priority load management and intelligent automatic monitoring.
- Save space with compact width and ability to line up units.
Wszystkie parametry znajdują się poniżej w karcie produktu
Do you need help? Do you have any questions?Ask a question and we'll respond promptly, publishing the most interesting questions and answers for others.